Availability: | |
---|---|
FXO-CT2250
Applications
● Small and medium metal parts
● Composite materials
● Power semiconductors
● Biological samples
● Ceramic devices
Features
▲ The maximum load-bearing stage of the stage is 30kg, and the testable sample is 300×600mm
▲ Automatic positioning of the best resolution
▲ Rapid reconstruction, combined with high-precision reconstruction in designated areas, accurately analyze customer concerns
▲ 3D point cloud image slice extraction from any angle, accurate analysis
▲ Multi-scale 2D image enhancement, more prominent details
▲ The scanning process is simple and the reconstruction imaging is fast
technical parameter
System parameters | Spatial resolution: >3μm |
Minimum defect resolution: 1.5μm | |
Contrast Resolution: Less than 1% | |
Measurement error: (1.5+L/200) μ m | |
Radiation protection: <1μ Sv/h, in line with the national GBZ117-2015 standard | |
Maximum sample diameter: 300mm | |
Maximum sample length: 600mm | |
Maximum weight of sample: 30kg | |
X-ray source | Voltage: 225kV |
Minimum focal spot: <3μm | |
Type: open tube | |
detector | Pixel matrix: 3072X3072 |
Imaging area: 427mmX427mm | |
Pixel size: 139μm | |
Machine parameters | Equipment size: 2500mm (length) × 1500mm (width) × 1800mm (height) |
Equipment weight: about 5000kg | |
Power supply: 220VAC, 50/60Hz | |
Working environment: 0℃~40℃ / 30~85RH | |
Equipment power: 1.3KW | |
Software function | CT reconstruction and display, slice extraction display and analysis, DR real-time preview |
detection image
image 1
image 2
Applications
● Small and medium metal parts
● Composite materials
● Power semiconductors
● Biological samples
● Ceramic devices
Features
▲ The maximum load-bearing stage of the stage is 30kg, and the testable sample is 300×600mm
▲ Automatic positioning of the best resolution
▲ Rapid reconstruction, combined with high-precision reconstruction in designated areas, accurately analyze customer concerns
▲ 3D point cloud image slice extraction from any angle, accurate analysis
▲ Multi-scale 2D image enhancement, more prominent details
▲ The scanning process is simple and the reconstruction imaging is fast
technical parameter
System parameters | Spatial resolution: >3μm |
Minimum defect resolution: 1.5μm | |
Contrast Resolution: Less than 1% | |
Measurement error: (1.5+L/200) μ m | |
Radiation protection: <1μ Sv/h, in line with the national GBZ117-2015 standard | |
Maximum sample diameter: 300mm | |
Maximum sample length: 600mm | |
Maximum weight of sample: 30kg | |
X-ray source | Voltage: 225kV |
Minimum focal spot: <3μm | |
Type: open tube | |
detector | Pixel matrix: 3072X3072 |
Imaging area: 427mmX427mm | |
Pixel size: 139μm | |
Machine parameters | Equipment size: 2500mm (length) × 1500mm (width) × 1800mm (height) |
Equipment weight: about 5000kg | |
Power supply: 220VAC, 50/60Hz | |
Working environment: 0℃~40℃ / 30~85RH | |
Equipment power: 1.3KW | |
Software function | CT reconstruction and display, slice extraction display and analysis, DR real-time preview |
detection image
image 1
image 2