Availability: | |
---|---|
FXO-2D1300 X-RAY
Applications
● Automotive electronics, aerospace
● Diamond, wire harness
● SMT—BGA welding inspection, electronic semiconductor packaging
● LED, lithium battery
Features
▲ 130KV imported ray source, high-resolution digital flat panel detector
▲ One-key navigation, easy and fast operation
▲ Industry-leading multi-angle detection function
▲ The maximum tiltable angle is 45°
▲ Stage size: 500mm × 4 00mm
▲ Independent research and development of multi-functional image processing system
▲ Multi-type measurement functions (distance, diameter, void ratio, tin climbing height)
▲ Multi-point CNC editing and positioning function
▲ Test point stepping NG, OK mark
technical parameter
X-ray source | Maximum voltage: 130kV |
Maximum current: 300μA | |
Minimum focal spot: 5μm | |
detector | Pixel matrix: 1536X1536 |
Pixel size: 85μm | |
Multi-angle detection | Multi-angle detection: concentric rotation, the platform does not tilt horizontally; |
Maximum tiltable angle: 45° | |
Stage | Stage size: 500mm × 400mm |
Maximum load: 10kg | |
Machine parameters | Equipment dimensions: 1100mm (length) × 1150mm (width) × 1700mm (height) |
Equipment weight: about 1500kg | |
Power supply: 220VAC, 50/60Hz | |
Working environment: 0℃~40℃ / 30~85RH | |
Equipment power: 1.3KW | |
Safety | Safety door interlocking measures: X-ray cannot be started if the door is not closed properly, the front door will be automatically locked and cannot be opened when the radiation is started, if the door is forced to be opened by external force when the radiation is started, the radiation will be forced to power off before the door is opened. |
Radiation leakage dose rate: <1μ Sv/h, in line with the national GBZ117-2015 standard | |
Software function | Image processing: self-developed multi-function image processing system |
Navigation system: high-definition automatic navigation plus real-time location tracking function, accurate and fast movement to the selected test point | |
Point editing: According to the multi-product measurement, perform positioning editing and save the position program, which can be called at any time later, and more than 1000 models can be added and saved according to product requirements | |
Test point labeling: You can choose between time and place when testing automatically according to the edited program. Move the position at regular intervals or determine NG by personnel, and then perform the next point test after OK, which can effectively prevent personnel from missing inspection. | |
Multi-color recording of the location information of the judgment points: When the automatic positioning test is performed according to the edited program, the judgment results are marked with different colors on the simulated position map according to the operator's judgment results, which is convenient for selection. | |
Measurement function: void calculation, three-point diameter measurement, parallel distance measurement, polygon measurement function | |
Annotation function: arrow standard, text annotation standard | |
Level 3 authority management: administrator, engineer, operator |
detection image
image 1
image 2
image 3
image 4
Applications
● Automotive electronics, aerospace
● Diamond, wire harness
● SMT—BGA welding inspection, electronic semiconductor packaging
● LED, lithium battery
Features
▲ 130KV imported ray source, high-resolution digital flat panel detector
▲ One-key navigation, easy and fast operation
▲ Industry-leading multi-angle detection function
▲ The maximum tiltable angle is 45°
▲ Stage size: 500mm × 4 00mm
▲ Independent research and development of multi-functional image processing system
▲ Multi-type measurement functions (distance, diameter, void ratio, tin climbing height)
▲ Multi-point CNC editing and positioning function
▲ Test point stepping NG, OK mark
technical parameter
X-ray source | Maximum voltage: 130kV |
Maximum current: 300μA | |
Minimum focal spot: 5μm | |
detector | Pixel matrix: 1536X1536 |
Pixel size: 85μm | |
Multi-angle detection | Multi-angle detection: concentric rotation, the platform does not tilt horizontally; |
Maximum tiltable angle: 45° | |
Stage | Stage size: 500mm × 400mm |
Maximum load: 10kg | |
Machine parameters | Equipment dimensions: 1100mm (length) × 1150mm (width) × 1700mm (height) |
Equipment weight: about 1500kg | |
Power supply: 220VAC, 50/60Hz | |
Working environment: 0℃~40℃ / 30~85RH | |
Equipment power: 1.3KW | |
Safety | Safety door interlocking measures: X-ray cannot be started if the door is not closed properly, the front door will be automatically locked and cannot be opened when the radiation is started, if the door is forced to be opened by external force when the radiation is started, the radiation will be forced to power off before the door is opened. |
Radiation leakage dose rate: <1μ Sv/h, in line with the national GBZ117-2015 standard | |
Software function | Image processing: self-developed multi-function image processing system |
Navigation system: high-definition automatic navigation plus real-time location tracking function, accurate and fast movement to the selected test point | |
Point editing: According to the multi-product measurement, perform positioning editing and save the position program, which can be called at any time later, and more than 1000 models can be added and saved according to product requirements | |
Test point labeling: You can choose between time and place when testing automatically according to the edited program. Move the position at regular intervals or determine NG by personnel, and then perform the next point test after OK, which can effectively prevent personnel from missing inspection. | |
Multi-color recording of the location information of the judgment points: When the automatic positioning test is performed according to the edited program, the judgment results are marked with different colors on the simulated position map according to the operator's judgment results, which is convenient for selection. | |
Measurement function: void calculation, three-point diameter measurement, parallel distance measurement, polygon measurement function | |
Annotation function: arrow standard, text annotation standard | |
Level 3 authority management: administrator, engineer, operator |
detection image
image 1
image 2
image 3
image 4